Highlight:
Support Lead-acid battery and Acting Battery,voltage range:6V~60V
Can display voltage,percent of battery,charging time at the same time through LCD
The function is very powerful,realizes the automatic charge control, the control charge time, also may set up and uploads the corresponding parameter through the serial port
Parameter Setting:
a) Press and hold the SET key to enter the setting interface
b) Switch the parameters you want to set by short press SET
c) After the selection of parameters, it can be set by the UP/DOWN key to support the short press, long press (fast increase or decrease), To set other parameters, repeat step b, c)
After all parameters are set, long press set key to exit and save
The Key Function:
In the Run interface (main interface):
Short press SET button to display the current set of parameters, Short press UP button, toggle display charge percentage and charging time
Short Press DOWN button, select Turn on/off relay enabling, if the relay can be closed, it will show `off ` as a reminder
Long press UP button, switch low power state
ON: No operation in 10 minutes turn off backlight
OFF: Backlight is always bright
Long press SET button,enter the parameter settings.
Additional Feature:
a) Charging time recording function: not open charging time control, the product will record a full time, when the entry time display interface, flashing display charging time, and then exit time display interface or next charge to open (relay conduction) when empty
b) Automatic parameter detection: When the parameters are set, exit, if volt-LI dn>= volt-HI UP, the system will flash display `ERR` as a reminder
c) Battery Access detection: This product attached to the battery, if not connected to the battery, the system will be shown in the downlink `NbE` as a reminder
Package Included:
1 * XY-L30A Battery Charging Control Module