|
aHR0cDovL2ZyZWVzaGlwLmNvLmty
- ¹èÅ͸® ÂøÅ»½Ä: ¾øÀ½
- ÃÖ´ë ÆÄÇü ĸó ¼Óµµ: 30, 000wfm/s
- ±â·Ï ±æÀÌ: as description
- ¸ðµ¨ ¹øÈ£: HT-1008C
- ½Ç½Ã°£ »ùÇøµ ¼Óµµ: as description
- µð½ºÇ÷¹ÀÌ ÇØ»óµµ: N/A
- µð½ºÇ÷¹ÀÌ Å©±â: ¾Æ¹«µµ
- ¹êµå ³Êºñ: ¹Ì¸¸ 60 MHzÀÇ
- µðÁöÅРä³Î: 8
- DIY ¿ëÇ°: ELECTRICAL
- ºê·£µå À̸§: Hantek
- ±Ù¿ø: CN (Á¤Ç°)
¿É¼ÇÁ¤º¸[(201530806)1008B][(200006155)1008C]
Signal generator function, can simulate crankshaft and camshaft signal.
Cost-effective Hantek PC USB 8CH Automotive Diagnostic Oscilloscope/DAQ/Programmable Generator: Highly efficient and cost -effective;
8 channels oscilloscope for vehicle testing;
Auto Ignition Probe;
2.4MSa/s real time sampling rate, 12bit vertical resolution;
spectrum analysis function;
10mV/div to 5V/div input sensitivity;
DAQ card function;
8 channels programmable generator which can analog signals of crankshaft, camshaft, etc.
(1) Vehicle Testing
First Diagnosis: Intake manifold vacuum & ignition, Petrol fumes adjusting valve vacuum & ignition, Idle exhaust ignition, Starting exhaust ignition
Ignition: primary and secondary
Sensor: Air Flow Meter, Camshaft, Crankshaft, Distributor, Lambda sensor, Throttle position
Bus Diagnosis: CAN bus data examine, CAN bus signal integrity, CAN bus LH long time acquisition, LIN bus
Performer: Petrol/Diesel
Starter and charging circuits
(2) Oscilloscope
8 channels oscilloscope, 2.4MSa/s real time sampling rate
12 bits vertical resolution, spectrum analysis function
(3) Programmable Generator
(4) Others
USB 2.0 interface plug and play, and no need extra power supply;
More than 20 types of automatic testing function, a similar interface with benchtop oscilloscope, easy to use;
NOTE: Software support: Windows NT, Window 2000, Windows XP, VISTA, Windows 7,Window 8,Window 10
Model |
Hantek1008C |
Oscilloscope Mode |
Vertical |
Analog Channel |
8 |
Input Impedance |
Resistance: 1MΩ |
Input Sensitivity |
10mV/div to 5V/div |
|
Input Coupling |
DC |
Resolution |
12 bits |
Horizontal |
Memory Depth |
4K |
Max. Input |
400V (DC+AC Peak) |
Real-Time Sampling Rate |
2.4MSa/s |
Time Base Range |
1ns/div to 20000s/div(1-2-5 sequences) |
Time Base Precision |
±50ppm |
Trigger |
Source |
CH1, CH2,CH3,CH4, CH5, CH6,CH7,CH8 |
Mode |
Edge |
X-Y Mode |
X-Axis Input |
CH1 |
Y-Axis Input |
CH2 |
Cursors and Measurement |
Voltage Measurement |
Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase,Vavg, Vrms, Vcrms, Preshoot, Overshoot |
Time Measurement |
Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle |
Cursors Measurement |
Horizontal ,Vertical, Track, Auto Measure Modes |
Waveform Signal Process |
|
+,- , x,÷, FFT, Invert |
Voltage Range |
|
10mV to 5V/div @ x 1 probe |
100mV to 50V/div @ x 10 probe |
10V to 5000V/div @ x 1000 probe |
100V to 50000V/div @ x 10000 probe |
200mV to 100V/div @ 20:1 |
Current Range |
|
100mA to 50.0A/div @ CC65(20A) |
1000mA to 500.0A/div @ CC65(65A) |
1A to 100.0A/div @ CC650(60A) |
10A to 1000.0A/div @ CC650(650A) |
1A to 200.0A/div @CC1100(100A) |
10A to 2000.0A/div @CC1100(1100A) |
Cursor |
|
Time/frequency difference, voltage difference |
FFT |
|
Rectangular, Hanning, Hamming, Blackman Window |
Math |
|
Addition, subtraction, multiplication, division |
Programmable Generator |
Channel |
|
8 |
Output Level |
|
LVTTL |
Frequency Range |
|
0-250kHz |
Interface |
|
USB 2.0 |
Power |
|
No need extra power supply |
Measurement |
Size |
185 x 150 x 27 (mm) |
Weight |
0.35KG |
1008C live shot:
Function Selection
There are three functions of vehicle diagnosis, oscilloscope and signal generator, including 78 types of vehicle diagnosis function. One Button Screenshot Save the current waveform and generate pictures. Storage location is optional and easy to find.
Reference Waveform
Over 80 types of standard reference waveform inside and can be callout or close with one button. It is convenient to be compared. Measurement Method
20 types of automatic measurement method which can be callout or close with one button. It is convenient and visual to read out the result.
Print
The result can be printed with one button and generate diagnosis report which is easy to be saved and recorded.
REF Comparison Waveform
The user can save the waveform as REF format and callout it again when you need to compare the two waveforms catched in different time.
Data Storage
The diagnosis result can be saved as the format of txt, csv, rfc, xls, doc, jpg and etc. It is convenient to be checked and compared later.
8CH Vehicle Diagnosis
8CH signal can be measured simultaneously. The measurement voltage of each channel can be adjusted independently. You can choose to open or close each channel.
Waveform Recor Support to record and replay the waveform. The waveform can be save into the computer hard disk and easy to read. There is no limit to the record time which can long-time measure and record the waveform for troubleshooting.
Multilanguage Support
Support the display surface in Chinese, English, German language, and it can be switched freely. Cursor Measurement
Support 4 types of cursor measurement mode -cross,track, horizontal, and vertical.It`s easy to read out the time and voltage of irregular signal.
Color and Lightness
The background color is optional as user`s preference. And the lightness of waveform and gridding is settable.
USB Communication
USB2.0 power supply + communication interface, plug and play, and support hot plugging.
Signal Generator
Signal generator function, can simulate crankshaft and camshaft signal.
|
|
|
|
|